Data Platform
NodePort - CVEN: Illumination map arrows are not correct (E-97387)
Traffic sent from an external client to a NodePort Service in a Kubernetes Cluster appears destined for the backing pod or host workload rather than for the service in the Illumination Map. No workaround is available.
Flow timestamp incorrect in Illumination for inbound-only or outbound-only reported flows (E-96595)
The flow timestamp that is shown in Illumination is not reliable for ingress-only or egress-only reported flows.
Workaround: Use Explorer to see the correct timestamp.
A large app_stats log file (8GB and more) is continuing to grow (E-95636)
On some systems, logrotate for the internal log files is sometimes not successful, which causes these files to continue to grow in size. No workaround is available.