Skip to main content

Illumio Core What's New and Release Notes 23.2

Known Issues in 23.2.31-VEN

  • Policy sync error thrown following Solaris VEN upgrade (E-121220)

    A policy sync error was thrown after upgrading a VEN on a Solaris workload to release 23.2.31. The error appeared after switching the VEN from Idle to any other mode. Workaround: If you've encountered this issue, upgrade to VEN release 24.2.20 or later.

  • AIX / Solaris 10 policy update fails in some circumstances (E-118539)

    Updating policy on AIX and Solaris 10 workloads fails if the workloads are in Full Enforcement mode and flow visibility is turned off. This issue is caused by incorrectly generated syntax. This is a known issue. Workaround: Go to Servers & Endpoints > Workloads, select AIX/Solaris 10 workloads that are in Full Enforcement mode, and then in the Visibility drop-down menu enable flow visibility by making sure the setting isn't Off.

  • Re-activating a deactivated VEN fails on AIX workloads (E-118055)

    If you deactivate a VEN installed on an AIX workload and later re-activate it, activation fails and a 401 error is thrown. This is a known issue. Workaround: After you deactivate the VEN, remove the backup folder under the VEN's data directory. WIth the backup folder removed, re-activation succeeds.