Skip to main content

Illumio Core What's New and Release Notes 23.2

Enterprise Server

  • Draft Policy Decision shows empty (E-107172)

    When running a draft query on a traffic table with cleared filters, users encountered an empty Draft Policy Decision column in the report. This issue is resolved.

  • Rule reordering not working for Intra-Scope rules if the ruleset includes an Extra-Scope rule (E-107148)

    In the new user interface, users were unable to reorder Intra-Scope rules within rulesets also containing Extra-Scope rules, or the other way around. This issue is resolved.

  • Services Windows: Process/Service-Based: delete port/protocol functionality failing (E-107099)

    When users added a single port and then added multiple items for Windows service-based processes, the process paths, and port names displayed incorrectly. When users then deleted a single port, data not marked for deletion were nonetheless deleted. These issues are resolved.

  • Some buttons in the Services UI were disabled (E-107097)

    After opening the Edit mode for any service with Operating System attribute All Operating Systems: Port-Based and adding a new Service Destination, the Add and Save buttons on the page were disabled. This issue is resolved and those buttons are now enabled in this circumstance.

  • Ransomware Dashboard always shows a high Protection coverage score (E-106996)

    In an environment with no flow data for two weeks, the protection coverage score shown in the dashboard and workload summary pages is 100%. This issue is resolved.

  • Default collector filters/aggregation incorrectly filters TCP Multicast/Broadcast (E-106955)

    Multicast and Broadcast cannot be TCP, yet default filters for new organizations incorrectly included Multicast TCP and Broadcast TCP. The following filters have been removed from the default list:

    • Netbios 137: Action - Drop, Transmission - Broadcast, Protocol - TCP, Port - 137

    • WS Discovery 3702: Action - Drop, Transmission - Multicast, Protocol - TCP, Port - 3702

  • Workloads page not updating external IP changes (E-106892)

    Workloads page was not updating external IP changes to release 22.5. and 23.2. This issue is resolved.

  • Illumination Plus Explorer saved traffic filters missing (E-106770)

    In the new UI, the saved traffic filters were missing in Illumination Plus. This issue is resolved.

  • Events page showing repeated 'clone.detected' messages (E-106579)

    After upgrading from release 21.5 to 22.5, the Events page was flooded with 'clone.detected' messages up to 5 times per second. This issue is resolved.

  • Global Viewer seeing "Add Rule" option in the UI Map (E-106288)

    A user with the Global Viewer role was able to see the option "Add Rule" in the UI by mistake. This issue is resolved.

  • On-Prem 21.5.34 Workload Filter Inconsistency (E-106223)

    Using multiple filters for the workload page that includes IP addresses might have produced an inaccurate result set. This issue is resolved.

  • Unable to edit Label in the Scope of a duplicated Ruleset (E-106200)

    Users were unable to see the ENV label type until they remove the ENV labels from the source in the Extra-scope rules contained in the Ruleset. This issue is resolved.

  • "All blocked" filter not showing flows blocked by deny rules (E-106163, E-106140)

    When "All Blocked" filter was used, the flows blocked by the "deny" rules were not showing up. This issue is resolved.

  • UI does not allow copying of IPs from the traffic view (E-106030)

    In the new UI, users were unable to copy IPs from the Traffic view. This issue is resolved.

  • PCE upgrade failure from PCE version 22.2.x and earlier to 22.5.20 and later with endpoint VENs (E-105999)

    The PCE upgrade failed in the `illumio-pce-db-management migrate` step when upgrading from PCE version 22.2.x and earlier to 22.5.20 and later when endpoint VENs were present before the PCE upgrade. This issue is resolved.

  • Workloads filter returned an incomplete list (E-105920) Specifying a particular subnet when filtering for workloads returned an incomplete list if any of the workloads had more than one interface in that subnet. This issue is resolved.

  • Mesh: Re-renders repeatedly. Interactions are not working (E-105167)

    Hover and brush interactions on Mesh have nit not been working properly and images re-render repeatedly. This issue is resolved.

  • Menu option "Core Services" appeared in error (E-105141)

    In a cluster in which Core Services was not enabled, the Infrastructure > Core Services option appeared in the left pane. This issue is resolved. 'Core Services' no longer appears when it's not enabled in the cluster.

  • After upgrade, the VEN could lose connectivity to the PCE (E-105022)

    After upgrading the VEN to 22.5.10, it could lose connectivity with the PCE. This issue only occurred with PCEs that were part of a Supercluster deployment. This issue is resolved. After upgrading the VEN to 22.5.22, the VEN can connect with PCEs in a Supercluster.

  • OS, Severity, and Port Type should be omitted in the service edit (E-104301, E-106881)

    Ransomware attributes OS, Severity, and PortType were added to a non-ransomware port and protocol for a ransomware service.

    In the Service editing page, attributes specific to ransomware services are now placed in a clearly differentiated part of the page.