Known Issues in Release 24.2.20-VEN
Issue | Description | Status |
---|---|---|
E-123299 | CLI required to upgrade certain Amazon Linux VENs You must use a command line to upgrade certain VEN versions installed on Amazon Linux workloads. There are two ways to upgrade a VEN:
When to use which method? Use the CLI upgrade method when upgrading pre-22.5.30 VENs to release 22.5.30 or later on Amazon Linux workloads. The upgrade fails if you try to use the PCE UI upgrade method in this scenario. Use either method for these upgrade scenarios on Amazon Linux workloads:
| Works as designed |
E-122188 | In some cases, policy sync error occurs when a VEN operates in a web proxy environment Given an environment where a web proxy is configured to direct the VEN to use the proxy to communicate with the PCE and the VEN is switched to Selective mode, new policy may not be accepted even if there is no Deny rule blocking communication to the proxy. Workaround: add an Allow rule allowing communication to the proxy. | Unresolved |