Skip to main content

What's New and Release Notes 25.2

Resolved Issues in 1.1.0 LW-VEN

Issue

Description

Status

E-119190

LW-VEN activation failed on non-UTF-8 legacy Windows workloads

LW-VEN activation failed on workloads configured for non-US languages. This happened because LW-VEN version 1.0.1 doesn't support non-UTF-8 strings. This issue is fixed. Support for non-UTF-8 was added in LW-VEN 1.1.0.

Resolved

E-118952

Activate option appeared during "non-fresh" LW-VEN installation 

When installing an LW-VEN on a supported legacy Windows machine on which an LW-VEN is already activated, the option Start + Activate appeared, which was unexpected. As this wasn't a fresh installation, only the Start option should've appeared, not Start+Activate. This issue is resolved. Now, only Start appears during non-fresh installations.

Resolved

(E-118764

Users weren't prompted during LW-VEN activation if activation command was run without options 

Attempting to activate LW-VEN failed if users issued the illumio-lwven-ctl activate command without options. A command prompt appeared but no prompts displayed and the activation hung. This issue is fixed.

Resolved

E-118600

LW-VEN 1.0.1 failed to apply 2008 firewall policy that contained very large port range 

The Windows Firewall rejected Illumio security policy rules that specified extremely large port ranges, resulting in policy not being applied. This issue is resolved. Rules exceeding 1000 ports are now split into multiple rules, and rules with large port ranges are no longer rejected. Caveat: Customers should keep in mind that applying a policy with a large port range may cause the Windows firewall to become unresponsive and take a long time to respond to any firewall command.

Resolved