Resolved Issues in 1.1.0 LW-VEN
Issue | Description | Status |
---|---|---|
E-119190 | LW-VEN activation failed on non-UTF-8 legacy Windows workloads LW-VEN activation failed on workloads configured for non-US languages. This happened because LW-VEN version 1.0.1 doesn't support non-UTF-8 strings. This issue is fixed. Support for non-UTF-8 was added in LW-VEN 1.1.0. | Resolved |
E-118952 | Activate option appeared during "non-fresh" LW-VEN installation When installing an LW-VEN on a supported legacy Windows machine on which an LW-VEN is already activated, the option Start + Activate appeared, which was unexpected. As this wasn't a fresh installation, only the Start option should've appeared, not Start+Activate. This issue is resolved. Now, only Start appears during non-fresh installations. | Resolved |
(E-118764 | Users weren't prompted during LW-VEN activation if activation command was run without options Attempting to activate LW-VEN failed if users issued the illumio-lwven-ctl activate command without options. A command prompt appeared but no prompts displayed and the activation hung. This issue is fixed. | Resolved |
E-118600 | LW-VEN 1.0.1 failed to apply 2008 firewall policy that contained very large port range The Windows Firewall rejected Illumio security policy rules that specified extremely large port ranges, resulting in policy not being applied. This issue is resolved. Rules exceeding 1000 ports are now split into multiple rules, and rules with large port ranges are no longer rejected. Caveat: Customers should keep in mind that applying a policy with a large port range may cause the Windows firewall to become unresponsive and take a long time to respond to any firewall command. | Resolved |